.6/1kV 90Â Deg.C IEC60332-3-22 60331-21 IEEE45 AS3004.2 LSZH Fire
Siz awg/ |
e kcmil |
Min. Bend Radius inch |
Nom. Ins. OD inch |
Nom. Cable OD inch |
Current Rating amp |
Approx. Wt. lb/kft |
Approx. Wt. w/alum. braid lb/kft |
Approx. Wt. w/bronze braid lb/kft |
| 7c |
16 |
|
[[""]] |
.6/1kV 90Â Deg.C IEC60332-3-22 60331-21 IEEE45 AS3004.2 LSZH Fire |
2.88 |
0.146 |
0.575 |
11 |
170 |
201 |
271 |
| Please contact your rep |
|
| 7c |
14 |
|
[[""]] |
.6/1kV 90Â Deg.C IEC60332-3-22 60331-21 IEEE45 AS3004.2 LSZH Fire |
3.13 |
0.162 |
0.625 |
17 |
218 |
251 |
327 |
| Please contact your rep |
|
| 12c |
16 |
|
[[""]] |
.6/1kV 90Â Deg.C IEC60332-3-22 60331-21 IEEE45 AS3004.2 LSZH Fire |
3.73 |
0.146 |
0.745 |
8 |
280 |
319 |
409 |
| Please contact your rep |
|
| 12c |
14 |
|
[[""]] |
.6/1kV 90Â Deg.C IEC60332-3-22 60331-21 IEEE45 AS3004.2 LSZH Fire |
4.05 |
0.162 |
0.810 |
12 |
364 |
407 |
505 |
| Please contact your rep |
|
| 19c |
16 |
|
[[""]] |
.6/1kV 90Â Deg.C IEC60332-3-22 60331-21 IEEE45 AS3004.2 LSZH Fire |
4.58 |
0.146 |
0.915 |
8 |
423 |
471 |
581 |
| Please contact your rep |
|
| 19c |
14 |
|
[[""]] |
.6/1kV 90Â Deg.C IEC60332-3-22 60331-21 IEEE45 AS3004.2 LSZH Fire |
4.98 |
0.162 |
0.995 |
12 |
552 |
604 |
723 |
| Please contact your rep |
|
| 24c |
16 |
|
[[""]] |
.6/1kV 90Â Deg.C IEC60332-3-22 60331-21 IEEE45 AS3004.2 LSZH Fire |
5.30 |
0.146 |
1.060 |
7 |
578 |
633 |
760 |
| Please contact your rep |
|
| 24c |
14 |
|
[[""]] |
.6/1kV 90Â Deg.C IEC60332-3-22 60331-21 IEEE45 AS3004.2 LSZH Fire |
5.78 |
0.162 |
1.155 |
11 |
752 |
812 |
950 |
| Please contact your rep |
|
| 27c |
16 |
|
[[""]] |
.6/1kV 90Â Deg.C IEC60332-3-22 60331-21 IEEE45 AS3004.2 LSZH Fire |
5.40 |
0.146 |
1.080 |
7 |
591 |
647 |
777 |
| Please contact your rep |
|
| 27c |
14 |
|
[[""]] |
.6/1kV 90Â Deg.C IEC60332-3-22 60331-21 IEEE45 AS3004.2 LSZH Fire |
5.90 |
0.162 |
1.180 |
11 |
776 |
837 |
979 |
| Please contact your rep |
|
| 33c |
16 |
|
[[""]] |
.6/1kV 90Â Deg.C IEC60332-3-22 60331-21 IEEE45 AS3004.2 LSZH Fire |
5.80 |
0.146 |
1.160 |
6 |
690 |
751 |
889 |
| Please contact your rep |
|
| 33c |
14 |
|
[[""]] |
.6/1kV 90Â Deg.C IEC60332-3-22 60331-21 IEEE45 AS3004.2 LSZH Fire |
6.35 |
0.162 |
1.270 |
10 |
911 |
977 |
1128 |
| Please contact your rep |
|
| 37c |
16 |
|
[[""]] |
.6/1kV 90Â Deg.C IEC60332-3-22 60331-21 IEEE45 AS3004.2 LSZH Fire |
6.03 |
0.146 |
1.205 |
6 |
743 |
806 |
950 |
| Please contact your rep |
|
| 37c |
14 |
|
[[""]] |
.6/1kV 90Â Deg.C IEC60332-3-22 60331-21 IEEE45 AS3004.2 LSZH Fire |
6.58 |
0.162 |
1.315 |
10 |
985 |
1054 |
1211 |
| Please contact your rep |
|
Based on IEEE 45-2002 Table 25 for cables installed in free air, single banked @ 45°C ambient.
There is a +5% tolerance to the NOMINAL values due to manufacturing process variations. TriCab is not liable for any errors, omissions, etc., and reserves the right to modify specifications at any time.
Issue 11.0