Shipboard 3C
shorepower
0.6/1KV 110°C°C 
m |
ze m² |
Min. Bend Radius mm |
Nom. Cond. OD mm |
Nom. Ins. OD mm |
Nom. Cable OD mm |
Current Rating amp |
Approx. Wt. kg/km |
|---|---|---|---|---|---|---|---|
| 3C | 1.5 | 31 | 1.6 | - | 10.4 | 16 | 120 |
| 3C | 2.5 | 35 | 2.1 | - | 11.5 | 21 | 160 |
| 3C | 4 | 38 | 2.6 | - | 12.6 | 28 | 210 |
| 3C | 6 | 42 | 3.2 | - | 13.9 | 36 | 280 |
| 3C | 10 | 49 | 4.0 | - | 16.2 | 50 | 400 |
| 3C | 16 | 56 | 5.2 | - | 18.8 | 67 | 596 |
| 3C | 25 | 66 | 6.3 | - | 22.0 | 89 | 846 |
| 3C | 35 | 74 | 7.4 | - | 24.6 | 110 | 1131 |
| 3C | 50 | 84 | 8.9 | - | 28.0 | 137 | 1555 |
Continuous current carrying capacities are calculated assuming 40° ambient temperature in free air, flexible unenclosed touching. For other installation methods, please refer to our current ratings table.
| Conductor Comparison - TriCab versus Class 5 & 6 (approximate no.of wires) |
| Size mm² | 50 | 70 | 95 | 120 | 150 | 185 | 240 | 300 | 400 | 500 | 630 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| TriCab | 658 | 969 | 1216 | 1672 | 2052 | 2508 | 3256 | 4144 | 5368 | 6832 | 8784 |
| Class5 | 378 | 342 | 465 | 587 | 734 | 905 | 1174 | 1468 | 1958 | 1710 | 2155 |
| Class6 | 662 | 927 | 1258 | 1589 | 1987 | 1401 | 1817 | 2272 |